GarrettCom 6K32TRC Switch User Manual


 
Magnum 6K32T & 6K32TRC Managed Switch Installation and User Guide 05/07)
70
www GarrettCom com
..
The actual connection procedure is very straightforward. Simply connect the
leads to the Magnum unit, beginning with ground. Ensure that each lead is securely
tightened.
Note: The GND should be hooked up first. The 6K32T & 6K32TRC unit has a floating
ground, so the user may elect to Ground either + or - terminal to suit the customer’s
use.
Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or
125VDC, always use a digital voltmeter to measure the output voltage of the power
supply and determine the lead which is more “+ve potential”. The more “+ve” voltage
lead from 48V or –48V supply must be connected to the post labeled “+”.
An ON-OFF manual switch is optional for DC power. This can be used to cut
off power connections and as a RESET for the Magnum 6K32T & 6K32TRC Switch.
B4.1 UL Requirements for DC-powered units
1. Minimum 18AWG cable for connection to a Centralized DC power source.
2. Minimum 14AWG cable for connection to a earthing wiring.
3. Use only with Listed 10 A circuit breaker provided in building installation.
4. “Complies with FDA radiation performance standards, 21 CFR subchapter J.”
or equivalent.
5. Fastening torque of the lugs on the terminal block: 9 inch-pound max.
6. Centralized DC Power Source cable securement, use at least Minimum 14AWG
four cable ties to secure the cable to the rac,k at least 4 inches apart, with the
first one located within 6 inches of the terminal block.
B5.0 OPERATION
Operation of Magnum 6K32T & 6K32TRC Switches with the optional -
48VDC, 24VDC and 125VDC power supply is identical to that of the standard AC-
powered models.
B6.0 ORDERING INFORMATION
To order the optional -48VDC power supply factory installed, add a suffix of “-
-48VDC” after the product’s standard model # Example: Magnum 6K32R & 6K32T &
6K32TRC -48VDC.
Similarly to order the optional 24VDC or 125VDC industrial specific power
supply factory installed, add a suffix of “ 24VDC” or “125VDC” after the product ‘s
standard model #. Example: Magnum 6K32T & 6K32TRC- 24VDC, Magnum 6K32T
& 6K32TRC-125VDC.