Magnum 6K8-Series Industrial Field Switch Installation and User Guide (04/07)
2.2.9 Frame Buffering and Flow Control
Magnum 6K8-Series’s are store-and-forward switches. Each frame (or packet)
is loaded into the Switch’s memory and inspected before forwarding can occur. This
technique ensures that all forwarded frames are of a valid length and have the correct
CRC, i.e., are good packets. This eliminates the propagation of bad packets, enabling all
of the available bandwidth to be used for valid information.
While other switching technologies (such as "cut-through" or
"express") impose minimal frame latency, they will also permit bad frames to propagate
out to the Ethernet segments connected. The "cut-through" technique permits collision
fragment frames (which are a result of late collisions) to be forwarded which add to the
network traffic. Since there is no way to filter frames with a bad CRC (the entire frame
must be present in order for CRC to be calculated), the result of indiscriminate cut-
through forwarding is greater traffic congestion, especially at peak activity. Since
collisions and bad packets are more likely when traffic is heavy, the result of store-and-
forward operation is that more bandwidth is available for good packets when the traffic
load is greatest.
When the Magnum 6K8-Series Switch detects that its free buffer queue space
is low, the Switch sends industry standard (full-duplex only) PAUSE packets out to the
devices sending packets to cause “flow control”. This tells the sending devices to
temporarily stop sending traffic, which allows a traffic catch-up to occur without
dropping packets. Then, normal packet buffering and processing resumes. This flow-
control sequence occurs in a fraction of a second and is transparent to an observer.
Another feature implemented in Magnum 6K8-Series Switches is a collision-based flow-
control mechanism (when operating at half-duplex only). When the Switch detects that
its free buffer queue space is low, the Switch prevents more frames from entering by
forcing a collision signal on all receiving half-duplex ports in order to stop incoming
traffic. The flow control option is user configurable (enable/disable) through the setport
command of MSN-6K software as per the requirement of a network.
2.2.10 Managed Network Software (MNS-6K) for Magnum 6K8-Series
Magnum 6K8-Series comes with licensed MNS-6K Firmware (Rel 3.2), which
allows the configuration of the Magnum 6Ks as a Managed Switch and also allows other
18
www GarrettCom com
..