GarrettCom 6K8 Switch User Manual


 
Magnum 6K8-Series Industrial Field Switch Installation and User Guide (04/07)
DC Power Supply (Options)
-48VDC Power Input Voltage: -36 to -70 VDC
24VDC Power Input Voltage: 18 to 36VDC
125VDC Power Input Voltage: 88 to 300VDC
5VDC Power Input Voltage: (+) or (-) 5%
Std. Terminal Block: “ -, GND, + ”
Power Consumption: same as for AC models, see above
For DC internal power supplies at –48VDC, 24VDC and 125VDC,
including Dual Source options (
for continuity of operation when either of the
DC input sources are interrupted)
, see Appendices B and C.
Per-port MDI or MDIX on RJ-45
The copper daughter board has MDI-MDIX Auto-crossover on all the RJ-45
ports., and eliminate the use of cross-over cable between the devices. Also
port-specific user settings (such as FDX or HDX, copper 10/100 speed) can
be fixed using software commands.
Mountings:
Vertical mounting only Suitable for wall or DIN-Rail mounting
Agency Approvals
Magnum 6K8
UL listed (UL60950), cU, CE Emissions meet FCC Part 15 Class A
IEEE 1613 Class 2 Environmental Standard for Electric Power Substations
See also Note for Power Substations in Sections 3.2.4, 3.7.1 and 5.2.9
IEC 61850 EMC and Operating Conditions, class C for Power Substations
NEMA TS-2 and TEES for AC-powered and PoE-powered traffic control
equipment
Note: These products are tested and approved under IEC61850 for use in Class
C sheltered locations where neither temperature nor humidity are controlled.
The equipment needs to be protected against solar radiation, rainfall, other
precipitations and wind. UL has not approved these products for Annex-T
outdoor use.
Warranty: Three years, per UL 60950-temperature rating Made in USA
Email
sales@GarrettCom.com
for details.
4
www GarrettCom com
..