GarrettCom Magnum 700X Network Router User Manual


 
Magnum 700X Mini-Concentrators Installation and User Guide (05/98)
GARRETT
3
1.2 Specifications - Repeater Port Modules (RPMs)
RPM Type : BNC AUI DTE Fiber-mm Fiber-sgl.m TP*
Front Access yes yes yes yes yes yes
Connector Type BNC-f DB-15 f DB-15 m ST or SC Fiber-ST RJ-45
Partition (PART)LED yes yes yes yes yes yes
Receive (RX) LED yes yes yes yes yes yes
LINK LED n.a. n.a. n.a. yes yes yes
Switch on Face Plate yes** n.a. n.a. n.a. n.a. yes***
“Fiber-mm” is multi-mode cable, normally used for 10BASE-FL installations, up to 2.0Km.
“Fiber-sgl.m” is single-mode cable, used for distant installations, up to 10.0Km.
* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded
and shielded twisted pair wiring.
** Internal termination switch for BNC, no "T" connector is required.
*** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link,
no crossover cable is required.
1.3 Specifications - Bridge Port Modules (BPMs)
BPM Type : BNC AUI Fiber TP*
Connector Type BNC(f) DB-15(f) ST RJ-45
Switch on FP yes** n.a. n.a. yes***
FWD-I LED yes yes yes yes
FWD-X LED yes yes yes yes
LINK LED n.a. n.a. yes yes
* The RJ-45 connector is shielded; it accepts RJ-45 eight-pin plugs for unshielded
and shielded twisted pair wiring.
** Internal termination switch for BNC, no "T" connector is required.
*** MDI-X (Media Dependent Interface - Crossover) switch for RJ-45 up-link,
no crossover cable is required.
NOTE: As of May, 1998, multiple BPMs (up to six) may be installed
in a 700X chassis to provide parallel bridging for the BPM’s attached
segments. This will increase network performance in applications
where there is significant local traffic on the bridged segments. (see
Section 4.2) Any mix of RPM and BPM types may be configured
together in a 700X, with a maximum of 6 BPMs and 7 total PMs per
unit..