Gateway S466 Computer Hardware User Manual


 
Chapter 7 Troubleshooting
75
BIOS Boot Error Messages
Message Problem Suggested Solution
Adapter BIOS Disabled.
No Logical Drives
Handled by BIOS
The ADAC Ultra2 S466
BIOS is disabled.
Sometimes the BIOS is
disabled to prevent
booting from the BIOS.
Enable the BIOS via the
ADAC Ultra2 S466 BIOS
Setup utility.
Host Adapter at Baseport
xxxx Not Responding
The BIOS cannot
communicate with the
adapter firmware.
Make sure ADAC Ultra2
S466 is properly installed.
No ADAC Ultra2 S466
Adapter
The BIOS cannot
communicate with the
adapter firmware.
Make sure ADAC Ultra2
S466 is properly installed.
Configuration of
NVRAM and drives
mismatch.
Run View/Add
Configuration option of
Configuration Utility.
Press any key to run the
Configuration Utility.
The configuration stored
in the ADAC Ultra2 S466
adapter does not match
the configuration stored in
the drives.
Press a key to run ADAC
Configuration Manager.
Choose View/Add
Configuration from the
Configure menu.
Use View/Add
Configuration to examine
both the configuration in
NVRAM and the
configuration stored on the
disk drives. Resolve the
problem by selecting one
of the configurations.
1 Logical Drive Failed A logical drive failed to
sign on.
Make sure all physical
drives are properly
connected and are powered
on.
Run ADAC Configuration
Manager to find out if any
physical drives are not
responding. Reconnect,
replace, or rebuild any
drive that is not
responding.