Shutdown
313872N 23
Shutdown
Short Term Shutdown
Perform Short Term Shutdown procedure if gun will not
be used for more than one hour.
1. Perform Pressure Relief Procedure on page 22.
2. Engage piston safety lock.
3. Trigger gun to retract purge rod.
4. While purge rod is retracted, remove any material
build-up on front poor tip and front packing.
5. While purge rod is retracted, spray Throat Seal
Lubricant (TSL) into the front nose.
6. Trigger gun five times in order to ensure material
does not build up on purge rod.
7. Detrigger gun and leave the air on.
8. Perform Grease the Gun on page 24.
Long Term Shutdown
Perform Long Term Shutdown procedure if gun will not
be used for more than 48 hours.
1. Perform Short Term Shutdown.
2. Flush Gun, see page 25.