Graco Inc. 313872n Webcam User Manual


 
Maintenance
26 313872N
Clean Outside of Gun
Wipe the outside of the gun with a compatible solvent.
See materials of construction info in Technical Data,
page 55. Use N-Methylpyrrolidone (NMP), Dynasolve
CU-6, Dzolv, or an equivalent solvent to soften cured
material. Applying a light coat of lubricant will make
future cleaning easier.
Clean Breather Plug
Remove and clean breather plug with compatible sol-
vent. See materials of construction info in Technical
Data, page 55. The breather plug is part of the solenoid
manifold assembly (30). See F
IG. 18. Use N-Methylpyr-
rolidone (NMP), Dynasolve CU-6, Dzolv, or an equiva-
lent to soften cured material. Applying a light coat of
lubricant will make future cleaning easier. Torque
breather plug to 30-40 in-lb (3.89-4.82 N•m).
Clean Fluid Manifold
1. Follow Pressure Relief Procedure.
2. Use 5/16 in. hex nut driver to remove fluid
manifold (AD).
3. Disconnect signal cable.
4. Clean fluid manifold fluid ports with compatible sol-
vent and brush whenever removed from gun. See
materials of construction info in Technical Data,
page 55. To prevent damaging the internal sealing
surfaces, do not use brush to clean inside diameter
of fluid ports. Fill fluid ports with grease if left
exposed, to seal out moisture. See F
IG. 19.
5. Install fluid manifold. Torque fluid manifold bolt to
20-30 in-lb (2.26-3.39 N•m).
6. Connect signal cable.
The solvents listed in this section may ignite if used in
flushing. Use them only for external cleaning.
The solvents listed in this section may ignite if used in
flushing. Use them only for external cleaning.
F
IG. 18: Breather Plug
ti14469a1
30
Breather
Plug
FIG. 19
Fluid Manifold Fluid Ports
TI2411a
ti19562a
AD