Graco Inc. 313872n Webcam User Manual


 
Models
4 313872N
Models
Orifice Flow Area Ratio Chart
In general, flow area ratio should be equal to material ratio but will be influenced by material viscosity. The ideal flow
area ratio is dependent on flow rates, material viscosity, and material ratio. Choose the correct size orifices to equal-
ize fluid pressures at the proportioner.
Part
Purge Rod
Diameter
in. (mm)
Orifice Size
in. (mm) Handle Type
257999 0.250 (6.35) 0.031 (0.79) Handheld
24C932 0.250 (6.35) 0.031 (0.79) Auto
Available Orifice Flow Area Ratios
Dia-
meter 0.016 0.020 0.024 0.028 0.031 0.035 0.039 0.042 0.047 0.052 0.055 0.060 0.063 0.067 0.073 0.086
Flowrate Increases as Diameter Increases=>
0.016 1.0 1.6 2.3 3.1 3.8 4.8 5.9 6.9 8.6 10.6 11.8 14.1 15.5 17.5 20.8 28.9
0.020 1.6
1.0 1.4 2.0 2.4 3.1 3.8 4.4 5.5 6.8 7.6 9.0 9.9 11.2 13.3 18.5
0.024 2.3 1.4
1.0 1.4 1.7 2.1 2.6 3.1 3.8 4.7 5.3 6.3 6.9 7.8 9.3 12.8
0.028 3.1
2.0 1.4 1.0 1.2 1.6 1.9 2.3 2.8 3.4 3.9 4.6 5.1 5.7 6.8 9.4
0.031 3.8 2.4 1.7 1.2
1.0 1.3 1.6 1.8 2.3 2.8 3.1 3.7 4.1 4.7 5.5 7.7
0.035 4.8 3.1 2.1 1.6 1.3
1.0 1.2 1.4 1.8 2.2 2.5 2.9 3.2 3.7 4.4 6.0
0.039 5.9 3.8 2.6 1.9 1.6 1.2
1.01.21.51.82.0 2.4 2.6 3.0 3.5 4.9
0.042 6.9 4.4 3.1 2.3 1.8 1.4 1.2
1.0 1.3 1.5 1.7 2.0 2.3 2.5 3.0 4.2
0.047 8.6 5.5 3.8 2.8 2.3 1.8 1.5 1.3
1.0 1.2 1.4 1.6 1.8 2.0 2.4 3.3
0.052 10.6 6.8 4.7 3.4 2.8 2.2 1.8 1.5 1.2
1.0 1.1 1.3 1.5 1.7 2.0 2.7
0.055 11.8 7.6 5.3 3.9 3.1 2.5
2.01.71.41.11.0 1.2 1.3 1.5 1.8 2.4
0.060 14.1 9.0 6.3 4.6 3.7 2.9 2.4
2.0 1.6 1.3 1.2 1.01.11.21.52.1
0.063 15.5 9.9 6.9 5.1 4.1 3.2 2.6 2.3 1.8 1.5 1.3 1.1
1.0 1.1 1.3 1.9
0.067 17.5 11.2 7.8 5.7 4.7 3.7
3.0 2.5 2.0 1.7 1.5 1.2 1.1 1.0 1.2 1.6
0.073 20.8 13.3 9.3 6.8 5.5 4.4 3.5
3.0 2.4 2.0 1.8 1.5 1.3 1.2 1.0 1.4
0.086 28.9 18.5 12.8 9.4 7.7 6.0 4.9 4.2 3.3 2.7 2.4 2.1 1.9 1.6 1.4
1.0
Flowrate Increases as Diameter Increases =>