10.4 Modifying the Setting Values – “set”
Command
The “set” command is used to modify the setting values of this
print server. The format of the “set” command is as follows :
set argument_name value
The value will be written into the system configuration. For
example, if you want to set the IP address of the print server to
192.168.1.250, type the “set ip ‘192.168.1.250’” command and
the IP of the print server will be changed:
admin# set ip ’192.168.1.250’
If you enter only “set,” the system will list all arguments of the
“set” command and the command format.
The following table lists all the arguments whose value can be
modified by “set” command:
Argument Description Example
psname Print server name set psname ‘PS001’
password Login password set password ‘1234’
username Login username set username ‘admin’