HP (Hewlett-Packard) 418191-001 Server User Manual


 
Specifications 74
Specifications
In this section
Environmental specifications .................................................................................................................... 74
Server blade specifications...................................................................................................................... 74
Environmental specifications
Specification Value
Temperature range*
Operating 10°C to 35°C (50°F to 95°F)
Shipping -40°C to 60°C (-40°F to 140°F)
Storage -20°C to 60°C (-4 to 140°C)
Maximum wet bulb temperature 30°C (86°F)
Relative humidity
(noncondensing)**
Operating 10% to 90%
Shipping 10% to 90%
Storage 10% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70
Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Server blade specifications
Specification Value
Height 5.56 cm (2.19 in)
Depth 50.95 cm (20.06 in)
Width 18.16 cm (7.15 in)
Weight (maximum) 5.9 kg (13.00 lb)
Weight (no drives installed) 5.33 kg (11.75 lb)