HP (Hewlett-Packard) 633407-001 Server User Manual


 
Removal and replacement procedures 68
8.
Close and lock the heatsink retaining latches.
9. Install the air baffle ("Air baffle" on page 31).
10. If the PCI riser cage was removed, install the PCI riser cage ("PCI riser cage" on page 32).
11. Install the access panel ("Access panel" on page 30).
12. Install the server into the rack.
13. Power up the server.
DIMMs
IMPORTANT: This server does not support mixing RDIMMs and UDIMMs. Attempting to mix
these two types causes the server to halt during BIOS initialization.
To identify the DIMMs installed in the server, see "DIMM slot locations ("DIMM identification" on page 95)."
To remove the component:
1. Power down the server (on page 25).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend ("Extend the server from the rack" on page 26) or remove ("Remove the server from the rack" on
page 27) the server from the rack.
4. Remove the access panel ("Access panel" on page 30).
5. Remove the air baffle ("Air baffle" on page 31).