HP (Hewlett-Packard) B6191-90029 Computer Monitor User Manual


 
Chapter 6
Special Procedures
Fibre Channel Arbitrated Loop Hub Monitor
131
Repeat Frequency: 1 day (1440 minutes)
Severity Action: Notify for all levels
The hub monitor also uses the following settings to configure the SNMP environment used by the hub. Note
that two of these settings (HUB_COUNT and HUB_X_IP_ADDRESS) are required to indicate to the monitor what
hubs should monitored. Changes that involve adding or deleting hubs to the configuration file while the
monitor is running will be invoked at the next polling interval, or following the selection of the (E)nable
Monitoring option from the Hardware Monitoring Request Manager (monconfig).
Table 6-1 PSM Configuration File Fields
Setting
Default
Value Description
HUB_COUNT value none Identifies the number of hubs (value) the monitor will
be responsible for monitoring.
This setting is required.
HUB_X_IP_ADDRESS IP_address none Identifies the IP address for each hub the monitor will
monitor. The “X” placeholder is replaced by the number
assigned to the hub, and “IP_address” is replaced by the
IP address of the hub. There must be a separate setting
for each hub.
This setting is required.
SITE_SNMP_GET_COMMUNITY
text
HUB_X_SNMP_GET_COMMUNITY
text
public These settings define the SNMP community assigned to
the hubs being monitored. The SITE setting is used for
all hubs, unless overridden by a HUB_X setting for the
specific hub identified by X.
The text string cannot contain embedded spaces.
SITE_LOCATION text
HUB_X_LOCATION text
none These settings define the text string used to identify the
hub location in log messages. The SITE setting is used
for all hubs, unless overridden by a HUB_X setting for
the specific hub identified by X.
The text string cannot contain embedded spaces.
SITE_CONTACT text
HUB_X_CONTACT text
none These settings define the text string used to identify the
contact person in log messages. The SITE setting is
used for all hubs, unless overridden by a HUB_X setting
for the specific hub identified by X.
The text string cannot contain embedded spaces.
SITE_SNMP_RETRY value
HUB_X_SNMP_RETRY value
3 These settings define the SNMP retry value in seconds.
The SITE setting is used for all hubs, unless overridden
by a HUB_X setting for the specific hub identified by X.
Valid values are 1 - 5.
SITE_SNMP_TIMEOUT value
HUB_X_SNMP_ TIMEOUT value
2 These settings define the SNMP timeout value in
seconds. The SITE setting is used for all hubs, unless
overridden by a HUB_X setting for the specific hub
identified by X.
Valid values are 1 - 5.