HP (Hewlett-Packard) E1Z75UT#ABA Personal Computer User Manual


 
Rated Input Current 5.5A
1
This system utilizes an active power factor corrected power supply. This allows the system to pass the CE mark requirements
for use in the countries of the European Union. The active power factor corrected power supply also has the added benefit of
not requiring an input voltage range select switch.
SFF specifications
Chassis (in the desktop position)
Height
Width
Depth
3.95 in
13.3 in
14.9 in
10.0 cm
33.8 cm
37.9 cm
Approximate Weight 16.7 lb 7.6 kg
Weight Supported (maximum distributed load in desktop position) 77 lb 35 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
NOTE: Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct
sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options
installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
Power Supply
Operating Voltage Range
Rated Voltage Range
1
Rated Line Frequency
Operating Line Frequency
90-264 VAC
100-240 VAC
50-60 Hz
47-63 Hz
Standard Efficiency
High Efficiency
240W STD active PFC
240W 92% efficient active PFC / 240W 90%
efficient active PFC
SFF specifications
229