HP (Hewlett-Packard) E3S36UT#ABA Personal Computer User Manual


 
Table 9-1 Numeric Codes and Text Messages (continued)
Control panel message Description Recommended action
2201-MEBx Module did not checksum
correctly
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the
computer.
4. If the error persists, replace the system
board.
2202-PMM Deallocation Error during MEBx
cleanup
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the
computer.
4. If the error persists, replace the system
board.
2203-Setup error during MEBx execution MEBx selection or exit resulted in a setup
failure.
1. Reboot the computer.
2. Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3. If the memory configuration was
recently changed, unplug the power
cord, restore the original memory
configuration, and reboot the
computer.
4. If the error persists, replace the system
board.
2204-Inventory error during MEBx execution BIOS information passed to the MEBx
resulted in a failure.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version.
3. If the error still persists, replace the
system board.
2205-Interface error during MEBx execution MEBx operation experienced a hardware
error during communication with ME.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version.
3. If the error still persists, replace the
system board.
POST Numeric Codes and Text Messages 179