HP (Hewlett-Packard) E3S36UT#ABA Personal Computer User Manual


 
Table 9-1 Numeric Codes and Text Messages (continued)
Control panel message Description Recommended action
2230-General error during MEBx execution Error occurred during MEBx execution
which fails into the “General” grouping.
Status information displayed along with the
error provides further clarity into the failure.
MEBx handles transference of information
between the system BIOS and ME
firmware.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version and ME firmware
version.
3. If the error still persists, replace the
system board.
2231-ME error during MEBx execution Error occurred during MEBx execution
which fails into “ME” grouping.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version and ME firmware
version.
3. If the error still persists, replace the
system board.
2232-AMT error during MEBx execution Error occurred during MEBx execution
which fails into “AMT” grouping.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version and ME firmware
version.
3. If the error still persists, replace the
system board.
2233-HECI error during MEBx execution Error occurred during MEBx execution
which fails into “MEI or HECI” grouping.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version and ME firmware
version.
3. If the error still persists, replace the
system board.
2239-ME image lock failure Special system configurations with reduced
ME firmware image require BIOS control of
ME firmware upgrading. A failure has
occurred after the ME firmware update
process in which the BIOS could not relock
the ME firmware region.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version and ME firmware
version.
3. If the error still persists, replace the
system board.
2240-ME image unlock failure Special system configurations with reduced
ME firmware image require BIOS control of
ME firmware upgrading. A failure has
occurred prior to the ME firmware update
process in which the BIOS could not unlock
the ME firmware region.
1. Reboot the computer.
2. If the error persists, update to the latest
BIOS version and ME firmware
version.
3. If the error still persists, replace the
system board.
Invalid Electronic Serial Number Electronic serial number is missing. Enter the correct serial number in Computer
Setup.
POST Numeric Codes and Text Messages 181