HP (Hewlett-Packard) N1200-320 Network Router User Manual


 
N1200-320 4Gb Network Storage Router user and service guide 53
Current, previous, and last assert trace displays
These three Utilities menu screens show trace information.
The Current Traces screen shows data since the network storage router was last booted.
The Previous Traces screen shows data from the last boot cycle.
The Last Assert Traces screen shows data since the last assertion.
Trace buffers can be cleared by selecting either the Clear Current Traces option or the Clear Assert Traces
option.
Clear current trace buffer or assert trace buffer
Trace buffers can be cleared by selecting either the Clear Current Traces option or the Clear Assert Traces
option. When the Clear Current Traces option is selected, a confirmation message appears to verify the
selection. If a response of Yes is given, the unit clears the current trace buffer. Current network storage
router activities are not disrupted while the buffer is cleared. Select the Submit button to finalize your
choice.
Event log settings
The Event Log Settings screen is used to configure Event Log filters (see Figure 32).
Figure 32 Event Log settings screen
Event Log settings:
Disable/Enable Logging
Emergency Events
Alert Events
Critical Events
Error Events
INBAND Controller management functionality is monitored and recorded
Queue Element Debugging capability for specific network storage router resources
Table 5 Trace Settings
Setting Description