HP (Hewlett-Packard) PCI-9111DG/HR Network Card User Manual


 
60 C/C++ Library
Visual Basic (Windows 95)
W_9111_AD_INT_Start (ByVal cardNo As Integer, ByVal auto_scan
As Integer, ByVal ad_ch_no As Integer, ByVal ad_gain As Integer,
ByVal count As Integer, ad_buffer As Integer, ByVal c1 As
Integer, ByVal c2 As Integer) As Integer
@ Argument
cardNo: the card number of PCI-9111 card initialized.
auto_scan: 0: autoscan is disabled.
1: autoscan is enabled.
ad_ch_no: A/D channel number.
If the auto_scan is set as enable, the selection
sequence of A/D channel is: 0, 1, 2, 3, ... , [ad_ch_no], 0,
1, 2, 3, ... , [ad_ch_no], ... .
If the auto_scan is set as disable, only the data input
from [ad_ch_no] is converted.
ad_gain: A/D analog input range, the possible values are:
AD_B_10_V, AD_B_5_V, AD_B_2_5_V,
AD_B_1_25_V, AD_B_0_625_V,
count: the number of A/D convertion
ad_buffer: the start address of the memory buffer t store the AD
data, the buffer size must large than the number of AD
conversion.
c1: the frequency devider of Timer#1.
c2: the frequency devider of Timer#2.
@ Return Code
ERR_InvalidADChannel
ERR_AD_InvalidGain
ERR_InvalidTimerValue
ERR_NoError
5.40 _9111_AD_FFHF_INT_Start
@ Description
This function is used to initialize and start up AD FIFO Half Full Interrupt
Transfer mode. This function could perform A/D conversion N times by
using pacer trigger and perform data transfer by using AD FIFO Half Full
Interrupt Transfer. It takes place in the background and will not stop until
the N blocks of conversion has been completed or your program execute
_9111_AD_INT_Stop() function to stop the process. After executing this
function, it is necessary to check the status of the operation by using the