HP (Hewlett-Packard) PCI-9111DG/HR Network Card User Manual


 
62 C/C++ Library
5.41 _9111_AD_INT_Status
@ Description
This function is used to check the status of interrupt operation. The
_9111_AD_INT_Start() is executed on background, therefore you can
issue this function to check the status of interrupt operation. While all the
specified counts of data are acquired, the interrupt status will be changed
to “AD_INT_STOP”.
@ Syntax
C/C++ (DOS)
U16 _9111_AD_INT_Status (U16 cardNo, U16 *status, U16 *count)
C/C++ (Windows 95)
U16 W_9111_AD_INT_Status (U16 cardNo, U16 *status, U16 *count)
Visual Basic (Windows 95)
W_9111_AD_INT_Status (ByVal cardNo As Integer, status As
Integer, count As Integer) As Integer
@ Argument
cardNo: the card number of PCI-9111 card initialized.
status: the status of the INT data transfer, the valid status code
are the following:
AD_INT_RUN
AD_INT_STOP
count: the A/D conversion count number performed currently
@ Return Code
ERR_NoError
5.42 _9111_AD_FFHF_INT_Status
@ Description
This function is used to check the status of interrupt operation using AD
FIFO Half Full Interrupt Transfer Mode. The _9111_AD_FFHF_INT_Start
is executed on background, therefore you can issue this function to check
the status of interrupt operation. While all the specified blocks of data are
acquired, the interrupt status will be changed to
“AD_FFHF_BLOCK_FULL”.
@ Syntax
C/C++ (DOS)
U16 _9111_AD_FFHF_INT_Status (U16 cardNo, U16 *status, U16
*blockNo)