HP (Hewlett-Packard) VA 7400 Server User Manual


 
VA 7100/7400 Cluster Installation Guide
10/12/01 20
4. Click on Device Settings and observe that the Device Settings window for the selected LUN is displayed as
shown below. On the display below, use the pull-down menu to select the desired Load Balancing Policy.
5. Repeat steps 3 and 4 for each LUN that has been configured.
6. AutoPath configuration is now complete.
Secure Manager Setup
To set up Secure Manager for Windows 2000, proceed as follows:
1. Ensure that Secure Manager for Windows 2000 software has been installed. Refer to the Hardware Connections
and Applicable Documents/Reference Material paragraphs of chapter 2.
NOTE Secure Manager is not required if this cluster is the only host communicating with the virtual array.
If there are other hosts or clusters in the system, Secure Manager is required.
2. To enable Secure Manager, proceed as follows:
a. Open a DOS window, and type the following:
armfeature -a -f LUN_SECURITY_xxGB –k <LicenseKey> <SerialNUMBER>
b. To ensure that the Secure Manager feature has been installed, type the following:
Armfeature –r <serialnumber>