Connecting to a room controller 49
The following table lists the types of notifications generated in various situations.
Incorrect commands cause the following types of notifications:
No asterisk at start of command—no response
Unrecognized command name—command with “?” added
Command that is currently unavailable—command with “?” added
Invalid parameter—command with current value
Action command with unnecessary parameter—action command
Action command that is unavailable—action command
The following simplified example shows how the projector typically responds to a request to
change the active input source. Note that the three latter notifications are delayed.
This type of request... Generates this type of notification...
Modify a setting Echoes the request command and shows the resulting value:
Request: *BRT=65<CR>
Notification: *BRT=65<CR><LF>
Query a setting Echoes the request command and shows the resulting value:
Request: *CON=?<CR>
Notification: *CON=40<CR><LF>
Execute an action Echoes the request command:
Request: *NXT<CR>
Notification: *NXT<CR><LF>
Request: *RSRC=4<CR>
Notification: *RSRC=4<CR><LF> (acknowledges request)
*SRC=0<CR><LF> (projector is attempting to acquire source 4, and in the interim
has no valid source)
*SRC=4<CR><LF> (source 4 is now active)
*BRT=60<CR><LF> (brightness has been modified for source 4)
*CSPC=?<CR><LF> (color space is not supported for this input)