Honeywell 3310g Scanner User Manual


 
12 - 2
Depth of Field
Typical Performance
Guaranteed Performance
Note: Performance may be impacted by bar code quality and environmental conditions.
Focus Standard Range (SR) High Density (HD) Extended Range (ER)
Symbology Near Distance Far Distance Near Distance Far Distance Near Distance Far Distance
5 mil Code 39
in. 2.16 6.26 .87 4.92 5.35 8.66
mm 55 159 22 125 136 220
13 mil UPC
in. 1.53 17.13 1.18 7.48 2.32 20.31
mm 39 435 30 190 59 516
10 mil Data Matrix
in. 1.85 8.50 .63 5.59 4.76 10.79
mm 47 216 16 142 121 274
20 mil Data Matrix
in. 1.30 16.30 .75 8.23 2.05 19.13
mm 33 414 19 209 52 486
Focus Standard Range (SR) High Density (HD) Extended Range (ER)
Symbology Near Distance Far Distance Near Distance Far Distance Near Distance Far Distance
5 mil Code 39
in. 2.52 5.71 1.18 4.68 5.79 8.82
mm 64 145 30 119 147 224
13 mil UPC
in. 2.16 16.14 1.26 6.97 2.79 19.02
mm 55 410 32 177 71 483
10 mil Data Matrix
in. 2.44 7.68 .71 5.32 5.32 9.10
mm 62 195 18 135 135 254
20 mil Data Matrix
in. 1.85 14.84 .91 7.91 4.02 15.98
mm 47 377 23 201 102 406