When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Multiple Symbols
When this programming selection is turned On, it allows you to read multiple symbols with a single press of the scanner’s but-
ton. If you press and hold the button, aiming the scanner at a series of symbols, it reads unique symbols once, beeping (if
turned on) for each read. The scanner attempts to find and decode new symbols as long as the button is pressed. When this
programming selection is turned Off, the scanner will only read the symbol closest to the aiming beam. Default = Off.
No Read
With No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig Tool Scan Data Window (see
page 10-3), an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear. Default = Off.
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message (see Data
Formatting beginning on page 5-1). The hex code for the No Read symbol is 9C.
Required
On/Not Required
*Off
On
* Off
On
* Off