Honeywell 3310g Scanner User Manual


 
3 - 6
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s button when using serial commands to trigger the
scanner. Once the scanner has timed out, you can activate the scanner either by pressing the button or using a serial trig-
ger command. After scanning the Read Time-Out bar code, set the time-out duration (from 0-300,000 milliseconds) by
scanning digits on the Programming Chart inside the back cover, then scanning Save. Default = 30,000 ms.
Presentation Mode
Presentation Mode uses ambient light and scanner illumination to detect bar codes. When in Presentation Mode, the LEDs
remain dim until a bar code is presented to the scanner, then the aimer turns on and the LEDs turn up to read the code. If the
light level in the room is not high enough, Presentation Mode may not work properly
Scan the following bar code to program your scanner for Presentation Mode.
LED Illumination - Presentation Mode
If you wish to set the illumination LED brightness, scan one of the bar codes below. This sets the LED illumination for the
scanner when it is in Presentation Mode. (If the scanner is triggered manually, the LED illumination will switch to the setting
for a manual trigger. (See LED Illumination - Manual Trigger on page 3-5.) Default = High.
Note: The LEDs are like a flash on a camera. The lower the ambient light in the room, the brighter the LEDs need to be so
the scanner can “see” the bar codes.
Note: LED Illumination - Presentation Mode does not apply to Streaming Presentation™ Mode or Mobile Phone Read
Mode.
Read Time-Out
Presentation Mode
Off
Low
* High