IBM 6830/6831 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
030-00X-XXX
030-01X-XXX
SCSI interface failure
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-027-XXX
SCSI interface Configuration/Setup error
1. SCSI signal cable
2. Flash the system
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-03X-XXX
030-04X-XXX
SCSI interface error
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. installed System board
030-195-XXX
SCSI interface Test aborted by user
1. Information
2. Re-start the test, if necessary
030-196-XXX
SCSI interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
030-197-XXX
SCSI interface test warning
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
030-198-XXX
SCSI interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems
section
030-199-XXX
SCSI interface test failed, cause unknown
1. Go to the Undetermined problems
section
2. Flash the system and re-test
3. Replace component under function test
035-000-XXX
RAID interface Test Passed
1. No action
035-0XX-XXX
RAID interface Failure
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
035-195-XXX
RAID interface Test aborted by user
1. Information
2. Re-start the test, if necessary
Chapter 6. Symptom-to-FRU Index 53