IBM 6830/6831 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
071-199-XXX
Audio port test failed, cause unknown
1. Go to the Undetermined problems
section
2. Flash the system and re-test
3. Replace component under function test
071-25X-XXX
Audio port failure
1. Speakers
2. Audio card, if installed
3. System board
080-000-XXX
Game Port interface Test Passed
1. No action
080-XXX-XXX
Game Port interface Error
1. Remove the game port device and
re-test the system
080-195-XXX
Game Port interface Test aborted by user
1. Information
2. Re-start the test, if necessary
080-196-XXX
Game Port interface test halt, error threshold
exceeded
1. Press F3 to review the log file
2. Re-start the test to reset the log file
080-197-XXX
Game Port interface test warning
1. Make sure the component that is called
out is connected and/or enabled
2. Re-run test
3. Component that is called out in warning
statement
4. Component under test
080-198-XXX
Game Port interface test aborted
1. If a component is called out, make sure
it is connected and/or enabled
2. Flash the system and re-test
3. Go to the Undetermined problems
section
080-199-XXX
Game Port interface test failed, cause
unknown
1. Go to the Undetermined problems
section
2. Flash the system and re-test
3. Replace component under function test
086-000-XXX
Mouse Port interface Test Passed
1. No action
086-001-XXX
Mouse Port interface Presence
1. Mouse
2. System board
086-032-XXX
Mouse Port interface Device controller
failure
1. Mouse
2. System board
086-035-XXX
Mouse Port interface Reset
1. Mouse
2. System board
086-040-XXX
Mouse Port interface IRQ failure
1. Run Setup
2. Mouse
3. System board
086-195-XXX
Mouse Port interface Test aborted by user
1. Information
2. Re-start the test, if necessary
Chapter 6. Symptom-to-FRU Index 55