150 Hardware Maintenance Manual: xSeries 250
035-XXX-S99 (Failed RAID test
on PCI slot S. S = number of
failing PCI slot. Check System
Error Log before replacing a
FRU.)
1. Cable
2. SCSI Backplane
3. Adapter
035-XXX-SNN (Check System
Error Log before replacing a
FRU. S = number of failing
PCI slot; NN = SCSI ID of
failing fixed disk.)
1. Fixed Disk with SCSI ID NN on RAID adapter in
PCI slot S.
035-253-S99 (RAID adapter
initialization failure)
1. ServeRAID Adapter in slot S is not configured
properly. Obtain the basic and extended configuration
status and refer to the ServeRAID Hardware
Maintenance Manual for more information.
2. Cable
3. SCSI Backplane
4. Adapter
075-XXX-000 (Failed Power
Supply test)
1. Power Supply
089-XXX-001 (Failed
Microprocessor test)
1. VRM for Microprocessor 1
2. Microprocessor
089-XXX-002 (Failed Optional
Microprocessor test)
1. VRM for Optional Microprocessor 2
2. Optional Microprocessor
089-XXX-003 (Failed Optional
Microprocessor test)
1. VRM for Optional Microprocessor 3
2. Optional Microprocessor
089-XXX-004 (Failed Optional
Microprocessor test)
1. VRM for Optional Microprocessor 4
2. Optional Microprocessor
165-XXX-000 (Failed Service
Processor test)
1. Check error log for any I2C messages (see “I2C bus
fault messages” on page 169).
2. Remove ac power from system for 20 seconds, then
rerun service processor test. If problem persists,
proceed to step 3..
3. I/O Legacy Board. Before replacing the I/O Legacy
Board, ensure that I/O Legacy Board jumper J28 is not
installed (the default) when the error occurs.
180-XXX-000 (Diagnostics LED
failure)
1. Run Diagnostic LED test for the failing LED.
180-XXX-001 (Failed
information LED panel test)
1. Information LED Panel
2. Diagnostic LED Panel
3. I/O Legacy Board
180-XXX-002 (Failed
Diagnostics LED Panel test)
1. Diagnostics LED Panel
2. I/O Legacy Board
180-XXX-003 (Failed System
Board LED test)
1. System Board
180-XXX-004 (Failed Processor
Board LED test)
1. Processor/PCI Board
2. I/O Legacy Board
Error Code/Symptom FRU/Action