IBM 7RY Computer Hardware User Manual


 
Symptom-to-FRU index 149
For all error codes, replace/follow the FRU/Action indicated.
Error Code/Symptom FRU/Action
001-XXX-000 (Failed core tests) 1. Processor/PCI Board
001-XXX-001 (Failed core tests) 1. Processor/PCI Board
001-250-000 (Failed System
Board ECC)
1. Processor/PCI Board
001-250-001 (Failed Processor
Board ECC)
1. Processor/PCI Board
005-XXX-000 (Failed Video test) 1. Video Adapter (if installed)
2. I/O Legacy Board
011-XXX-000 (Failed COM1
Serial Port test)
1. I/O Legacy Board
011-XXX-001 (Failed COM2
Serial Port test)
1. I/O Legacy Board
014-XXX-000 (Failed Parallel
Port test)
1. I/O Legacy Board
015-XXX-001 (USB interface not
found. Board damaged.)
1. I/O Legacy Board.
015-XXX-015 (Failed USB
External Loopback Test)
1. Make sure parallel port is not disabled.
2. Re-run USB External Loopback Test.
3. I/O Legacy Board
015-XXX-198 (USB device
connected during USB test)
1. Remove USB devices from USB1 and USB2.
2. Re-run test.
3. I/O Legacy Board
020-XXX-000 (Failed PCI
Interface test)
1. Processor/PCI Board
2. System Board
020-XXX-001 (Failed Hot-Swap
Slot 1 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. Processor/PCI Board
020-XXX-002 (Failed Hot-Swap
Slot 2 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. Processor/PCI Board
020-XXX-003 (Failed Hot-Swap
Slot 3 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. Processor/PCI Board
020-XXX-004 (Failed Hot-Swap
Slot 4 PCI Latch test)
1. PCI Hot-Swap Latch Assembly
2. Processor/PCI Board
030-XXX-000 (Failed Internal
SCSI interface test)
1. I/O Legacy Board
030-XXX-00N (Failed SCSI test
on PCI slot N. Check system
error log before replacing a
FRU.)
1. Adapter
035-XXX-099 1. No adapters were found.
2. If adapter is installed re-check connection.