v IBM 5494 Remote Control Unit Planning Guide, GA27-3936
v IBM 5494 Remote Control Unit User’s Guide, GA27-3852
AS/400
Prompt AS/400 Parameter
5494
AS/400
Value 5494 Value NotesField Subfield
Local
adapter
address
ADPTADR H1 5 - - Values specified in the AS/400
line description (CRTLINTRN
command) and for the 5494
Remote Controller Unit must
match.
LAN
remote
adapter
address
ADPTADR 15 - - - Values specified for the AS/400
CRTCTLAPPC command and
for the 5494 Remote Control
Unit must match.
Local
location
name
LCLLOCNAME H1 1 - - Values specified for the AS/400
CRTCTLRWS command and
for the 5494 Remote Control
Unit must match. This will
probably match LCLLOCNAME
in the network attributes. This
value will probably match the
LCLLOCNAME in the network
attributes.
Link type LINKTYPE AA - *LAN 4 5494 configuration values must
match the values specified for
the LINKTYPE parameter on
the CRTCTLAPPC command.
For APPC controllers that
specify LINKTYPE(*SDLC), the
value specified in the 5494
configuration must be
compatible with the physical
interface (INTERFACE
parameter) specified on the
CRTLINSDLC command.
Select 4 for the network
connections.
Remote
control
point name
RMTCPNAME 13 - - - Values specified for the AS/400
CRTCTLAPPC command and
for the 5494 Remote Control
Unit must match.
Remote
network
identifier
RMTNETID 11 3 - - Values specified for the AS/400
CRTCTLAPPC and
CRTCTLRWS commands and
for the 5494 Remote Control
Unit must match. This will
probably match LCLNETID in
the network attributes and
H1:2.
Remote
location
name
RMTLOCNAME 12 - - - Values specified for the AS/400
CRTCTLRWS command and
for the 5494 Remote Control
Unit must match.
Example: Connecting an AS/400 to a 5494 controller connected by frame relay
Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.
Chapter 7. Communicating with remote workstation controllers 47