v IBM 5494 Remote Control Unit User’s Guide, GA27-3852
AS/400
Prompt
AS/400
Parameter
5494
AS/400
Value 5494 Value NotesField Subfield
Default
packet size
DFTPKTSIZE 5 1 64 0
128 1
256 2
512 3
Local
location
name
LCLLOCNAME H1 1 - - Values specified for the AS/400
CRTCTLRWS command and for the
5494 Remote Control Unit must
match. This will probably match
LCLLOCNAME in the network
attributes. This value will probably
match the LCLLOCNAME in the
network attributes.
X.25 link
protocol
LINKPCL 6 2 *QLLC 01
*ELLC 10
Link type LINKTYPE AA - *X25 1 5494 configuration values must
match the values specified for the
LINKTYPE parameter on the
CRTCTLAPPC command. For
APPC controllers that specify
LINKTYPE(*SDLC), the value
specified in the 5494 configuration
must be compatible with the
physical interface (INTERFACE
parameter) specified on the
CRTLINSDLC command.
Select 1 for communications using
X.25 lines.
X.25
network
level
NETLVL 6 5 1988 0 Used for X.25 communications only.
1984 1
1980 2
Remote
control
point name
RMTCPNAME 13 - - - Values specified for the AS/400
CRTCTLAPPC command and for
the 5494 Remote Control Unit must
match.
Remote
network
identifier
RMTNETID 11 3 - - Values specified for the AS/400
CRTCTLAPPC and CRTCTLRWS
commands and for the 5494
Remote Control Unit must match.
This will probably match LCLNETID
in the network attributes and H1:2.
Remote
location
name
RMTLOCNAME 12 - - - Values specified for the AS/400
CRTCTLRWS command and for the
5494 Remote Control Unit must
match.
Chapter 7. Communicating with remote workstation controllers 55