IBM AS/400 Network Router User Manual


 
Refer to Table 13 for an explanation on reason codes for failed program start requests.
Table 1. Reason Codes for Rejected Program Start Requests
Reason
Code Reason Description
401 Program start request received to a device that is not allocated to an active subsystem.
402 Requested device is currently being held by a Hold Communications Device (HLDCMNDEV) command.
403 User profile is not accessible.
404 Job description is not accessible.
405 Output queue is not accessible.
406 Maximum number of jobs defined by subsystem description are already active.
407 Maximum number of jobs defined by communications entry are already active.
408 Maximum number of jobs defined by routing entry are already active.
409 Library on library list is exclusively in use by another job.
410 Group profile cannot be accessed.
411 Insufficient storage in machine pool to start job.
412 System value not accessible.
413 QSERVER not started
501 Job description was not found.
502 Output queue was not found.
503 Class was not found.
504 Library on initial library list was not found.
505 Job description or job description library is damaged.
506 Library on library list is destroyed.
507 Duplicate libraries were found on library list.
508 Storage-pool defined size is zero.
602 Transaction program-name value is reserved but not supported.
604 Matching routing entry was not found.
605 Program was not found.
704 Password is not valid.
705 User is not authorized to device.
706 User is not authorized to subsystem description.
707 User is not authorized to job description.
708 User is not authorized to output queue.
709 User is not authorized to program.
710 User is not authorized to class.
711 User is not authorized to library on library list.
712 User is not authorized to group profile.
713 User ID is not valid.
714 Default user profile is not valid.
715 Neither password nor user ID was provided, and no default user profile was specified in the
communications entry.
718 No user ID.
722 A user ID was received but a password was not sent.
723 No password was associated with the user ID.
725 User ID does not follow naming convention.
726 User profile is disabled.
730 Password has expired.
801 Program initialization parameters are present but not allowed.
802 Program initialization parameter exceeds 2000 bytes.
803 Subsystem is ending.
804 Prestart job is inactive or is ending.
805 WAIT(NO) was specified on the prestart job entry and no prestart job was available.
806 The maximum number of prestart jobs that can be active on a prestart job entry was exceeded.
807 Prestart job ended when a program start request was being received.
Chapter 8. Troubleshooting communications problems 85