Intel BX80637I53350P Computer Hardware User Manual


 
Specification Update 11
BV60
XXXNo Fix
The Processor May Not Comply With PCIe* Equalization Preset Reflection
Requirements for 8 GT/s Mode of Operation
BV61
XXXNo FixProcessor May Issue PCIe* EIEOS at Incorrect Rate
BV62
XXXNo Fix
Reduced Swing Output Mode Needs Zero De-emphasis to be Supported in PCIe*
5GT/s Speed
BV63
XXXNo Fix
PCIe* Root-port Initiated Compliance State Transmitter Equalization Settings May
be Incorrect
BV64
XXXNo FixPCIe* Controller May Incorrectly Log Errors on Transition to RxL0s
BV65
XXXNo Fix
Reception of Certain Malformed Transactions May Cause PCIe* Port to Hang
Rather Than Reporting an Error
BV66
XXXNo FixPCIe* Link Width May Degrade After a Warm Reset
BV67
XXXNo FixMSR_PKG_Cx_RESIDENCY MSRs May Not be Accurate
BV68
XXXNo FixPCIe* Link May Not Enter Loopback.Active When Directed
BV69
XXXNo Fix
Execution of VAESIMC or VAESKEYGENASSIST With An Illegal Value for
VEX.vvvv May Produce a #NM Exception
BV70
XXXNo FixUnexpected #UD on VZEROALL/VZEROUPPER
BV71
XXXNo FixPCIe* Root Port May Not Initiate Link Speed Change
BV72
XXXNo FixSuccessive Fixed Counter Overflows May be Discarded
BV73
XXXNo Fix
Execution of FXSAVE or FXRSTOR With the VEX Prefix May Produce a #NM
Exception
BV74
XXXNo Fix
VM Exits Due to “NMI-Window Exiting” May Not Occur Following a VM Entry to the
Shutdown State
BV75
XXXNo Fix
Execution of INVVPID Outside 64-Bit Mode Cannot Invalidate Translations For 64-
Bit Linear Addresses
BV76
XXXNo FixPCIe* Controller May Not Properly Indicate Link Electrical Idle Condition
BV77
XXXNo FixPCIe* Controller May Not Enter Loopback
BV78
XXXNo FixLink Margin Characterization May Hang Link
BV79
XXXNo FixUnused PCIe* Lanes May Report Correctable Errors
BV80
XXXNo FixRDMSR of IA32_PERFEVTSEL{4-7} May Return Erroneous Information
BV81
XXXNo FixPCIe* Link May Fail Link Width Upconfiguration
BV82
XXXNo FixGraphics L3 Cache Parity Errors May Not be Detected
BV83
XXXNo Fix
A PCIe* Link That is in Link Disable State May Prevent DDR I/O Buffers From
Entering a Power Gated State
BV84
XXXNo FixREP MOVSB May Incorrectly Update ECX, ESI, and EDI
BV85
XXXNo FixPerformance-Counter Overflow Indication May Cause Undesired Behavior
BV86
XXXNo FixRDMSR of IA32_PERFEVTSEL4-7 May Return an Incorrect Result
BV87
XXXNo FixVEX.L is Not Ignored with VCVT*2SI Instructions
BV88
XXXNo Fix
Concurrently Changing the Memory Type and Page Size May Lead to a System
Hang
BV89
XXXNo FixMCI_ADDR May be Incorrect For Cache Parity Errors
Errata (Sheet 4 of 5)
Number
Steppings
Status ERRATA
E-1 L-1 N-0