94 ECB-870 User’s Manual
Display Type Has Changed Since Last Boot
Since last powering off the system, the display adapter has been changed. You must
configure the system for the new display type.
EISA Configuration Checksum Error
Please Run EISA Configuration Utility
The EISA non-volatile RAM checksum is incorrect or cannot correctly read the EISA slot.
This can indicate either the EISA non-volatile memory has become corrupt or the slot has
been configured incorrectly. Also be sure the card is installed firmly in the slot.
EISA Configuration Is Not Complete
Please Run EISA Configuration Utility
The slot configuration information stored in the EISA non-volatile memory is incomplete.
Note: When either of these errors appear, the system will boot in ISA mode, which allows you to run the
EISA Configuration Utility.
Error Encountered initializing Hard Drive
Hard drive cannot be initialized. Be sure the adapter is installed correctly and all cables
are correctly and firmly attached. Also be sure the correct hard drive type is selected in
Setup.
Error Initializing Hard Disk Controller
Cannot initialize controller. Make sure the cord is correctly and firmly installed in the bus.
Be sure the correct hard drive type is selected in Setup. Also check to see if any jumper
needs to be set correctly on the hard drive.
Floppy Disk Cntrlr Error Or No Cntrlr Present
Cannot find or initialize the floppy drive controller. Make sure the controller is installed
correctly and firmly. If there are no floppy drives installed, be sure the Diskette Drive
selection in Setup is set to NONE.
Invalid EISA Configuration
Please Run EISA Configuration Utility
The non-volatile memory containing EISA configuration information was programmed
incorrectly or has become corrupt. Re-run EISA configuration utility to correctly program
the memory.
NOTE: When this error appears, the system will boot in ISA mode, which allows you to run the EISA