Intel Server Board SE7501CW2 Installation and Integration Guide
Installing Chassis Standoffs
If your chassis does not have standoffs placed as shown,
you must rearrange them so they match the holes in the
server board. Failure to properly rearrange the metal
standoffs may cause the server board to malfunction and
permanently damage it. Your chassis may be different from
the illustration, but you must still arrange the standoffs
properly.
When using an Intel Server Chassis SC5200, positions 1, 4,
6, 20, 23, and 26 come preinstalled. You must install
standoffs in positions 7, 18, and 19. Install standoffs in the
eight positions marked P regardless of whether one or
two processors will be installed. Standoffs are included
with this chassis.
Installing the Rubber Bumper
Attach the rubber bumper to the chassis. The
bumper should cover the indicated chassis standoff
hole. On an Intel Server Chassis SC5200, the
standoff is marked ‘S’. On other chassis, place the
bumper approximately 3 inches (7.6 cm) below
and to the left of the standoffs marked P as shown.
Installing the Server Board
1. Place the board into the chassis,
making sure that the back panel’s
I/O shield and chassis standoffs align
correctly.
2. Attach the board with the included
screws at the ten locations shown.
Note:
If you are installing only one processor, you must also insert screws
into the four standoff locations around the CPU2 socket.
10