Symptom
Possible course
Solution
Oil leaks from
hydraulic ram
Ram packing worn
Plunger bent
Replace o-ring and
back-up ring with repair
set
Hydraulic platform
does not move up
Under pressure in
hydraulic system
Remove the wood
plate of the lifting
platform and unscrew
the valve on the oil-
tank pipe; move the
platform in up position
by hand and turn valve
screw tight
Page 21 of 28