16
External Control
7 About the external control
This monitor has two external control terminals.
• MAKE/TRIGGER terminal (RJ-45): The following external control systems are available.
(1) MAKE (make contact) system: Controls the monitor by short-circuiting the corresponding pin terminal to
the GND pin terminal, or disconnecting (opening) it (☞ below).
(2) TRIGGER (trigger) system: Controls the monitor by sending the pulse signal instantaneously to the
corresponding pin terminal (☞ below).
• RS-232C terminal (D-sub 9-pin): Controls the monitor with the RS-232C system. (☞ page 17)
• Control priority is as follows.
MAKE > TRIGGER, RS-232C, buttons and menu on the monitor
• You can use the external control even when “CONTROL LOCK” is set to “ON” (☞ page 15).
• When the monitor is off (on standby), external control is not available.
7 Using the MAKE/TRIGGER system
You can control the monitor by a personal computer or dedicated controller*
1
.
*
1
The controller is not commercially available. Consult your dealer if you need it.
The MAKE/TRIGGER terminal is configured as follows. You can assign a function to each pin terminal in
“REMOTE SETTING” (☞ “PIN1, PIN2, PIN3, PIN4, PIN5” on page 15).
Pin No. Pin name Pin No. Pin name
1
PIN1
5
PIN5
2
PIN2
6
PIN6 (TALLY)*
2
3
PIN3
7
PIN7 (ENABLE)*
3
4
PIN4
8
PIN8 (GND)
*
2
The 6th pin terminal controls turning on or off the tally lamp (available to control even when the 7th pin terminal is
invalid.)
*
3
The 7th pin terminal makes the external control valid/invalid. Make sure to control the terminal by the MAKE system.
• You cannot change the functions assigned to the pin terminals from 6th to 8th.
• When “FORMAT INDICATOR” in “FUNCTION SETTING” is set to “ON,” the TALLY lamp cannot be controlled
by the external control (☞ page 14)
• You cannot assign the same function to different pin terminals.
• The TRIGGER system switches each function by short-circuiting the pin terminal for about 1 second and
opening it.
To assign the functions to the pin terminals
For the operation procedure, see page 7.
1 Select “REMOTE SETTING” on the SET-UP MENU.
2 Set “TYPE SEL.” to “SET.”
3 Select a pin name (“PIN1” – “PIN5”) for which you want to assign a function, then select the function you want
to assign.
• For selectable functions, see the table on the right.
This is a female
terminal.
Functions controlled by the MAKE/TRIGGER system
Display Functions to be controlled Opening Short-circuiting
TALLY SEL Selects the color of the tally lamp. Green Red
SDI 1 Changes the input to “SDI 1.” Invalid Valid
SDI 2 Changes the input to “SDI 2.” Invalid Valid
VIDEO/COMPO. Changes the input to “VIDEO/COMPO.” Invalid Valid
MARKER The area marker and the safety marker indication Off On
FRAME
Indication of the area of the specified aspect ratio
Off On
C.MARKER The center marker indication Off On
MARK.SEL Selects the items of “MARKER”*
4
Non-“R-” items “R-” items
ASPECT Changes the aspect ratio. 4:3 16:9
STATUS Status display*
5
☞ “On the Status Display” on page 7
L.METER Audio level meter display *
6
TIME CODE Time code display Off On
SOURCE ID
☞ “SOURCE ID” on page 15
Off On
WAVE FORM
Wave form monitor display*
7
Off On
C. C. Closed caption display
*
8
COLOR OFF Color off Color Monochrome
SCR CHECK Screens check *
9
DYNAMIC Adjusts the picture to be suitable for a bright place. Off On
FOCUS ASSIST Helps to focus the picture. Off On
COLOR RANGE Reduces the difference of the luminance level specific to
the LCD panel.
Off On
MUTING Muting on/off Off On
— — — No function — —
*
4
Selects which functions in “MARKER” are activated, non-“R-” items or “R-” items (☞ page 11).
*
5
Displays the information shown when the button of the current input is pressed (☞ “On the Status Display” on page 7).
While controlling with the MAKE system, the information is displayed only at the moment of short-circuiting.
*
6
While controlling with the MAKE system, the level meter is switched between displayed (short-circuiting) and hidden
(opening). When “LEVEL METER ch” is set to “OFF,” the level meter is not displayed (“NO EFFECT” appears). While
controlling with the TRIGGER system, the number of the audio channels displayed is changed (between OFF, 12CH
and 8CH).
*
7
While controlling with the MAKE system, the wave form monitor will not disappear until opening the terminal even when
“AUTO OFF” is set to “ON.”
*
8
For analog composite signals (NTSC and B/W60 only). While controlling with the MAKE system, the closed caption
is switched between displayed (short-circuiting) and hidden (opening). When “CLOSED CAPTION” is set to “OFF,” the
closed caption is not displayed (“NO EFFECT” appears). While controlling with the TRIGGER system, the type of the
closed caption can be selected.
*
9
While controlling with the MAKE system, the screen is switched between normal screen (opening) and blue screen
(short-circuiting). While controlling with the TRIGGER system, the screen changes as follows:
Normal screen Red screen
Green screenBlue screen
DT-V9L3D_J_en.indb 16DT-V9L3D_J_en.indb 16 09.8.7 1:30:35 PM09.8.7 1:30:35 PM