NovaJet 500/630/700 Series Service Manual
ASSEMBLY/
DISASSEMBLY
Assembly\Disassembly 5-41
4. Perform steps 3 and 4 of the Remove the Trailing Cable
Assembly procedures to remove the Trailing Cable Assembly.
5. Perform steps 5 and 6 of the Remove the Stabilizer Bracket and
Encoder Strip procedures to remove the Stabilizer Bracket
Assembly.
6. Disconnect the Load Sensor connector at the J4 location on the
MPCB. Grasp the Load Sensor connector with the thumb and
forefinger and pull straight out.
7. Remove the seven screws that secures the Y-Arm Assembly to
the Platen. See Figure 5-24.
Figure 5-24. Y-Arm Installation/Removal.
8. The pinch rollers are held on by a small C clamp located on the
back of the Y-Arm Assembly. See Figure 5-25. While holding
the pinch roller, remove the C clamp and move the pinch roller
towards the front of the Y-Arm Assembly until it clears the back
of the Y-Arm Bracket.