Kodak 500 Printer User Manual


 
3-20 Maintenance
NovaJet 500/630/700 Series Service Manual
2. Place gauge against left side of shaft assembly allowing
micrometer tip to rest directly on top of shaft. See Figure 3-12.
Zero the gauge (this is to become the reference point).
MEASURE
SECOND
MEASURE
FIRST
MEASURE
LAST
ADJUST IF
NECESSARY
Figure 3-12. Measurement Positions for Slide Shaft.
3. Measure the right side (next to media alignment mark.)and
note the difference. Divide this amount by two.
4. Measure just off the center of the slide shaft and adjust the
center turnbuckle with an open ended wrench if required, for
the average value (the value found in step 3.) See Figure 3-13.
NOTE
The NovaJet 500/630/700 60 inch models have two turn-
buckles, so both of these need to be adjusted together for
the center position.