Kodak 500 Printer User Manual


 
NovaJet 500/630/700 Series Service Manual
MAINTENANCE
Maintenance 3-23
3. Place the test cartridge upright on a flat surface and ‘zero’ the
gauge by loosening the knob near the top and turning the dial
until the needle is at the ‘0’ position on the dial. Tighten the
knob. See Figure 3-16.
ZERO
GAUGE
ENSURE PRESSURE IS
PLACED ON THE REAR
OF THE CARTRIDGE
0
Figure 3-16. Zeroing the Micrometer Gauge.
4. Remove the Cyan ink cartridge. Snap the test cartridge with
the micrometer gauge into the position vacated by the Cyan
ink cartridge. See Figure 3-17. Ensure that the micrometer
can be read from the BACK of the printer.
Figure 3-17. Test Cartridge Installed.