NovaJet 500/630/700 Series Service Manual
MAINTENANCE
Maintenance 3-39
The Continuous Test will first prime the cartridges,
followed by a serial port test, parallel port test, a fast
deadband display and a color calibration display.
The deadband and color calibration displays are used only
as a visual inspection of the operating condition of the
printer. No adjustments can be performed while in the
Continuous Test mode.
A loopback Test Cable is required to correctly accomplish
the serial and parallel port tests. Install both ends of the
Loopback Cable before running this test. The Loopback Test
Cable is listed in Chapter 6.
After completing the deadband display, the test will begin
again with the prime and continue until power is removed.
Fan #1 and Fan #2 Tests - Tests the operation of the fans on the
printer. Fan #1 Test (while depressed) turns on the power
supply cooling fan and the suction fan inside the platen on
the right side of the printer. Fan #2 Test (while depressed)
turns on the suction fan inside the platen near the center of
the printer. The 42 inch printer does not have this second
suction fan, therefore, the Fan #2 Test is disabled.
Legs Test - Tests the condition of the leg harness connections
and the components of the power feed and take-up system.