Lantronix UDS100 Network Card User Manual


 
Using Monitor Mode UDS10/UDS100 User Guide
44
Using Monitor Mode Commands
The following commands are available in Monitor Mode. Many commands have an IP
address as an optional parameter (x.x.x.x). If the IP address is given, the command is
applied to another unit with that IP address. If no IP address is given, the command is
executed locally.
Note: All commands must be in capital letters, with blank spaces between
the settings.
Table 7-1. Monitor Mode Commands
Command Command Name Function
SF x.x.x.x Send Firmware Sends firmware to unit with IP address x.x.x.x.
VS x.x.x.x Version
Queries software header record (16-byte) of unit with
IP address x.x.x.x.
GC x.x.x.x Get Configuration
Gets configuration of unit with IP address x.x.x.x as
hex records.
SC x.x.x.x Send Configuration
Sets configuration of unit with IP address x.x.x.x from
hex records.
PI x.x.x.x Ping
Pings unit with IP address x.x.x.x to check device
status.
AT ARP Table Shows the unit’s ARP table entries.
TT TCP Connection Table Shows all incoming and outgoing TCP connections.
NC Network Connection Shows the unit’s IP configuration.
RS Reset Resets the unit’s power.
QU Quit Exits diagnostics mode.
G0, G1...GE,
GF
Get configuration from memory page
Gets a memory page of configuration information from
the device.
S0, S1... SE,
SF
Set configuration to memory page
Sets a memory page of configuration information on
the device.
Entering any of the commands listed above generates one of the following command
response codes:
Table 7-2. Command Response Codes
Response Meaning
0> OK; no error
1> No answer from remote device
2> Cannot reach remote device or no answer
8> Wrong parameter(s)
9> Invalid command