Lenovo 4217 Personal Computer User Manual


 
RAID Level 0 Striped disk array
Two hard disk drives minimum
Better performance without fault tolerance
RAID Level 1 Mirrored disk array
Two hard disk drives minimum
Improved read performance and 100% redundancy
RAID Level 5 Block-level striped disk array with distributed parity
Three hard disk drives minimum
Data striped at the byte level
Stripe error correction information
Better performance and fault tolerance
To install a new SAS hard disk drive, refer to the installation procedure in “Replacing a hard disk drive” in the
ThinkStation Hardware Installation and Replacement Guide.
Entering the Marvell BIOS Setup to congure SAS RAID
This section describes how to enter the Marvell BIOS Setup to congure SAS RAID.
1. Your computer must have a Marvell SAS adapter card (Marvell SAS controller) installed to congure
SAS RAID. For installing or replacing a Marvell SAS adapter card, refer to “Replacing an adapter card”
in the ThinkStation Hardware Installation and Replacement Guide.
2. Turn on the computer after you have installed the required number of SAS hard disk drives and the
Marvell SAS adapter card.
3. Press Ctrl+M when prompted to enter the Marvell BIOS Setup to congure SAS RAID.
Conguring the Marvell BIOS Setup to enable SAS RAID 0, 1, or 5
functionality
To enable SAS RAID 0, 1, or 5 functionality, use the Marvell BIOS Setup conguration utility as the SAS
conguration utility. This utility assumes that the system has the required number of hard disk drives.
1. Turn on your computer and press Ctrl+M when prompted to enter the Marvell BIOS Setup.
2. On the Marvell BIOS Setup screen, use the arrow keys to select RAID Cong and press Enter. The
RAID Cong menu opens.
3. From the RAID Cong menu, select Create array.
4. Use the arrow keys and the Enter key to select each free hard disk drive that you want to include
in the array.
5. Select Next and press Enter.
6. From the Create array menu, select RAID level and press Enter.
Note: Only the valid RAID levels will be active.
7. Select the SAS RAID level you want (RAID 0, RAID 1, or RAID 5) and press Enter.
8. From the Stripe size menu, you can change the stripe size or keep it as default.
9. Type a proper array name in the Array name eld.
10. Select Next and press Enter. When prompted, press Y to complete the array creation and RAID
conguration.
Chapter 7. Installing hard disk drives and conguring RAID (types 4105, 4157, 4217) 47