Lenovo 6394 Computer Hardware User Manual


 
Diagnostic Error Code FRU/Action
175-199-XXX Thermal Sensor(s) test failed, cause
unknown
1. See “Undetermined problems” on page 62
2. Flash the system and re-test. See “Updating (ashing)
BIOS from a CD-ROM or diskette” on page 139
3. Replace component under function test
175-250-XXX 175-251-XXX Thermal Sensor(s) limit error 1. Check fans
2. Check AC/DC power adapter voltages
3. Microprocessor
4. System board
185-000-XXX Asset Security Test Passed
No action
185-XXX-XXX Asset Security failure
1. Flash system
2. System board
185-278-XXX Asset Security Chassis Intrusion 1. Assure Asset Security Enabled
2. C2 Cover Switch
3. System board
201-000-XXX System Memory Test Passed
No action
201-XXX-XXX System Memory error
1. Replace the memory module called out by the test
2. System board
202-000-XXX System Cache Test Passed
No action
202-XXX-XXX System Cache error 1. Cache, if removable
2. System board
3. Microprocessor
206-000-XXX Diskette Drive Test Passed No action
206-XXX-XXX Diskette Drive error
1. Diskette Drive Cable
2. Check AC/DC power adapter voltages
3. Diskette drive
4. System board
215-000-XXX CD-ROM Drive Test Passed
No action
215-XXX-XXX CD-ROM Drive error 1. CD-ROM Drive Cable
2. Check AC/DC power adapter voltages
3. CD-ROM drive
4. System board
217-000-XXX Hard Disk Drive Test Passed No action
217-25X-XXX 217-26X-XXX Hard Disk Drive (IDE) error 1. Hard Disk Drive Cable
2. Check AC/DC power adapter voltages
3. Reseat the hard disk drive cable
4. Hard Disk drive (IDE)
5. System board
58 Hardware Maintenance Manual