4.3.5 Messages in Voting_CONTROL_GRP
The following control messages controls voting sessions and attendance check sessions in the CU.
Again, the message format descriptions have the same meaning as in section 3.4.3.
COMMAND_ITEM_VOTING_CONTROL_TYPE_OF_VOTING
Command item value: 1
Message format:
<START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <52> <1> <Type of Voting> <0> <CRC> <STOP>
The Type of Voting parameter defines, which type of voting session is to take place. Type of Voting is
defined prior to execution of a voting session.
Type of Voting Value Description
3-Button Voting 3 Three voting alternatives will be available
– typically Yes, Abstain and No.
5-Button Voting 5 Five voting alternatives will be available –
typically ++, +, 0, - and --.
COMMAND_ITEM_VOTING_CONTROL_SECRET_VOTING
Command item value: 3
Message format:
<START> ‘j’ <ID> <0> <MSB addr> <LSB Addr> <52> <3> <Secret Voting> <0> <CRC> <STOP>
The Secret Voting parameter defines, whether votes are kept secret by the system, or whether it is
acceptable for delegates to view votes cast by other delegates..
Secret Voting Value Description
Open voting 0 Votes are revealed by the DCS6000
system.
Secret Voting 1 Votes are kept secret by the DCS6000
system. Units do not reveal votes, and the
CU does not distribute status of cast votes
to external control units, only the
interim/final results.
VOTING_CONTROL_START_ATTENDANCE_CHECK
Command item value: 11
Message format: