Listen Technologies DCS 6000 Network Card User Manual


 
Danish Interpretation Systems Technical Specifications
Printed in Denmark
38
Message format:
<START> 'c' <ID> <MSB addr> <LSB addr> <53> <1> <18> <CRC> <STOP>
This message informs that a voting session is closed in the CU. Immediately before this message, the
CU has distributed the final voting result (VOTING_STATUS_VOTING_RESULTS).
VOTING_STATUS_VOTING_CANCELLED
Command item value: 19
Message format:
<START> 'c' <ID> <MSB addr> <LSB addr> <53> <1> <19> <CRC> <STOP>
This message informs that a voting session is cancelled by the CU. No voting result is available after
this.
VOTING_STATUS_INTERIM_VOTING_RESULTS
Command item value: 21
Message format:
<START> 'c' <ID> <MSB addr> <LSB addr> <53> <4> <21> <alternativ> <MSB result> <LSB result> <CRC>
<STOP>
This message includes the interim voting result of one of the voting alternatives:
Alternativ=1 Number of Yes-votes = 256*MSB result + LSB result
Alternativ=2 Number of Abstain-votes = 256*MSB result + LSB result
Alternativ=3 Number of No-votes = 256*MSB result + LSB result
VOTING_STATUS_VOTING_RESULTS
Command item value: 22
Message format:
<START> 'c' <ID> <MSB addr> <LSB addr> <53> <4> <21> <alternativ> <MSB result> <LSB result> <CRC>
<STOP>
This message includes the final voting result of one of the voting alternatives:
Alternativ=1 Number of Yes-votes = 256*MSB result + LSB result
Alternativ=2 Number of Abstain-votes = 256*MSB result + LSB result
Alternativ=3 Number of No-votes = 256*MSB result + LSB result
4.5.5 Messages in UNIT_ATTENDANCE_STATUS_GRP
This message group contains presence indications from microphone units, where the ‘Present’ button
has been pressed. The group is not split into command items. Instead, it includes information of up to 4