LSI SAS2 Computer Hardware User Manual


 
SAS2 Integrated RAID Solution User Guide Appendix A: | Commands
LSI Corporation Confidential
| August 2010 Page 39
Sample Output Following is an example of the information that the STATUS command returns when a
volume resynchronization is in progress:
Background command progress status for controller 0...
IR Volume 1
Volume ID : 6
Current operation : Synchronize
Volume status : Enabled
Volume state : Degraded
Physical disk I/Os : Not quiesced
Volume size (in sectors) : 70311936
Number of remaining sectors : 68250624
Percentage complete : 2.93%
Following is an example of the status information that the STATUS command returns if
a background volume operation is not in progress:
Background command progress status for controller 0...
IR Volume 1
Current operation : None
Volume ID : 6
Volume status : Enabled
Volume state : Optimal
Physical disk I/Os : Not quiesced
The possible values for the fields in the status data are as follows:
Current operation: Synchronize, Consistency Check, OCE, Background Init, or None
Volume status: Enabled or Disabled
Volume state: [Inactive] Optimal, Degraded, Missing, or Failed
Physical disk I/Os: Quiesced or Not quiesced
A.3.7 LIST Command The LIST command displays a listing of all controllers present in system, along with
each corresponding controller index. You use the controller index as an input
parameter for other SAS2IRCU commands.
Command Line sas2ircu list
Parameters None
Program Return Value 0x00 SUCCESS: Command completed successfully.
0x01 FAILURE: Command failed.
0x02 ADAPTER_NOT_FOUND: Cannot find specified adapter.
Sample Output Following is an example of the output of the LIST command. The format and fields in
the output may vary depending on the types of installed controllers.
Adapter Vendor Device SubSys SubSys
Index Type ID ID Pci Address Ven ID Dev ID
----- --------- ------ ------ ---------------- ------- ------
0 SAS2008 1000h 72h 00h:01h:00h:00h 1000h 00dah
1 SAS2008 1000h 72h 00h:05h:00h:00h 1000h 00dah