Cajun P220, P550, P550R Switch Release Notes, Release 4.0.1 25
Chapter 9 Additional Undocumented
Commands
The following sections list and describe commands that are not included in the Cajun P550/P220
Switch Command Line Reference Guide for Release 4.0.1.
NOTE: Refer to the Lucent online documentation web site at HTTP://pubs.lucentctc.com,
for an updated release of the Cajun P550/P220 Switch Command Line Reference Guide that has
been updated after the release date.
Buffering Commands
Table1-4 shows new and changed buffering commands added to Release 4.0.1.
Table 1-4: Buffering Commands
Old Command New Command New Definition/Argument
set buffering
fabric-port
<fabric-port-spec>
[routing]
{input|output} age-
timer {160-to-
320|640-to-1280}
N/A
<fabric-port-spec>fabric port specifier -
#/#, #/FORE, #/#-#/# on P550/P550R,
CPU,G1,G2,G3,G4,G5,G6,G7,A1 on P220G
CPU,G1,A1,1-12,13-24 on P220.
set buffering
fabric-port
<fabric-port-spec>
[routing]
{input|output}
hipri-alloc
{10|20|30|40|50}
N/A
The switch must be rebooted in order for
changes to this parameter to become effective.
<fabric-port-spec>fabric port specifier
(#/#, #/FORE, #/#-#/# on P550/P550R)
(CPU,G1,
G2,G3,G4,G5,G6,G7,A1 on P220G)
(CPU,G1,A1,1-12,13-24 on P220).
set buffering
fabric-port
<fabric-port-spec>
[routing]
{input|output}
hipri-service-ratio
{3-to-1|99-to-1|
999-to-1|9999-to-1}
N/A
<fabric-port-spec> fabric port specifier
- #/#, #/FORE, #/#-#/# on P550/R550R. CPU,
G1, G2, G3, G4, G5, G6, G7, A1 on P220G.
CPU, G1, A1, 1-12, 13-24 on P220.