Cajun P220, P550, P550R Switch Release Notes, Release 4.0.1 26
set buffering
fabric-port
<fabric-port-spec>
[routing]
{input|output} pri-
threshold {1|
2|3|4|5 |6|7|all-
frames-normal-
priority}
N/A
<fabric-port-spec> – fabric port specifier
- (#/#, #/FORE, #/#-#/# on P550/P550R)
(CPU,G1,G2,
G3,G4,G5,G6,G7,A1 on P220G) (CPU,G1,A1,1-
12,13-24 on P220).
set buffering port
<mod-port-spec>
output age-timer
{21|42|84|
168|336|672|1340}
set buffering port
<mod-swport-spec>
output age-timer
{21|
42|84|168|336|672|
1340}
Default: 168
<mod-swport-spec> – switch port specifier
- (#/# on P550/P550R) (A1...A4 on P220G)
(A1...A4, 1...24 on P220).
set buffering port
<mod-port-spec>
output hipri-alloc
{10|20| 30 |40|50}
set buffering port
<mod-swport-spec>
output hipri-alloc
{10 |20|30|40|50}
The switch must be rebooted in order for
changes to this parameter to become effective.
Default: 20
<mod-swport-spec> - switch port specifier -
(#/# on P550/P550R) (A1...A4 on P220G)
(A1...A4, 1...24 on P220).
set buffering port
<mod-port-spec>
output hipri-
service-ratio {1-
to-1|3-to-1|7-to-
1|15-to-1| 31-to-
1|63-to-1|127-to-
1|255-to-1|511-to-
1| 1023-to-1|2047-
to-1| 4095-to-
1|8191-to-1| 16383-
to-1|32767-to-1}
set buffering port
<mod-swport-spec>
output hipri-
service-ratio {1-
to-1|3-to-1 |7-to-
1|15-to-1| 31-to-
1|63-to-1| 127-to-
1|255-to-1| 511-to-
1|1023-to-1| 2047-
to-1|4095-to-1|
8191-to-1|16383-to-
1| 32767-to-1}
Default: 1023-to-1
<mod-swport-spec> - switch port specifier -
(#/# on P550/P550R) (A1...A4 on P220G)
(A1...A4, 1...24 on P220).
set buffering port
<mod-port-spec>
output pri-
threshold
{1|2|3|4|5|6|7|
all-frames-normal-
priority}
set buffering port
<mod-swport-spec>
output pri-
threshold
{1|2|3|4|5|6|7|
all-frames-normal-
priority}
Default: 4
<mod-swport-spec> – switch port
specifier - (#/# on P550/P550R) (A1...A4 on
P220G) (A1...A4, 1...24 on P220).
Table 1-4: Buffering Commands (Continued)
Old Command New Command New Definition/Argument