Maxtor 10K III Computer Drive User Manual


 
Installation
3-12 Maxtor Atlas 10K III
SCSI ID Pin Assignments (SCA-2 Connector Versions of the Disk Drive)
Note: 0 indicates an open circuit from +2.4 V to Vcc +0.5 V, and 1
indicates ground from 0.5 V to +0.4 V.
Maxtor Atlas 10K III drives have three Spin Up modes:
Option 1 Spin up occurs immediately when power is applied.
Option 2 Drive spin up occurs after a predetermined delay following power on.
Set the delay parameters with the MODE SELECT Command,
Maxtor (Vendor) Special Function Control Page (39h).The delay is
equal to a user-specified multiplier multiplied by the numerical SCSI
ID of the drive. This will give a staggered spin-up in multiple-drive
installations.
Option 3 Drive spin up is controlled by the START STOP UNIT command.
00 0 0 0
10 0 0 1
20 0 1 0
30 0 1 1
40 1 0 0
50 1 0 1
60 1 1 0
70 1 1 1
81 0 0 0
91 0 0 1
10 1 0 1 0
11 1 0 1 1
12 1 1 0 0
13 1 1 0 1
14 1 1 1 0
15 1 1 1 1