Maxtor 10K III Computer Drive User Manual


 
SCSI Description
5-8 Maxtor Atlas 10K III
Under SCSI-2 processing, the Extended Contingent Allegiance condition extends
Contingent Allegiance handling so the initiator has explicit control over the point at
which suspended (queued) commands are resumed. It allows the initiator to send a
REQUEST SENSE command and then send the non-tagged commands to access the
drives medium.
This action is provided to fix damage left by the failed command before permitting the
drive to continue with processing the queued commands.
The Extended Contingent Allegiance condition is enabled and disabled by the EECA
bit in the MODE SELECT Control Mode page. The Extended Allegiance Condition
differs from the Contingent Allegiance in that, under the Extended Contingent
Allegiance condition:
The drive sends an INITIATE RECOVERY message to the allegiance
initiator prior to returning the failed commands COMMAND
COMPLETE message. If the initiator rejects the INITIATE
RECOVERY message, the drive drops back to contingent allegiance
level of operation for the current error.
An ABORT message does not terminate the extended contingent
allegiance condition.
Non-tagged drive access commands from the allegianced initiator are
accepted by the drive and take priority over all queued commands.
QUEUE FULL status is returned if the host sends a tagged command.
The drive delays resuming or aborting the queued commands until a
RELEASE RECOVERY message is received from the initiator.
The extended contingent allegiance condition remains in effect until cleared by one
of the following:
Hard reset
BUS DEVICE RESET message from any initiator
RELEASE RECOVERY message from the allegianced initiator