SCSI Description
5-2 Maxtor Atlas 10K III
1. Relative Addressing is not supported by the drive. Therefore, in all I/O commands,
the RelAdr bit must be 0.
2. RESERVE and RELEASE are supported, as are third-party reservations. Extent
reservations are not supported.
3. The RECEIVE DIAGNOSTIC RESULTS and SEND DIAGNOSTIC DATA
commands implement vendor-unique pages to test the drive during the manufacturing
process. It is recommended that initiators specify only the non-page format variants of
these commands (PF=0), except for page 0x40.
PERSISTENT RESERVATION OUT 5Fh Sequential
READ (6) 08h Normal
READ (10) 28h Normal
READ BUFFER 3Ch Sequential
READ CAPACITY 25h Immediate
READ DEFECT DATA (10) 37h Sequential
READ DEFECT DATA (12) B7h Sequential
READ LONG 3Eh Sequential
READ SKIP MASK E8h Normal
REASSIGN BLOCKS 07h Sequential
RECEIVE DIAGNOSTIC RESULTS 1Ch Sequential
RELEASE 17h Sequential
RELEASE (10) 57h Sequential
REPORT LUNS A0h Sequential
REPORT DEVICE IDENTIFIER A3h Sequential
REQUEST SENSE 03h Immediate
RESERVE 16h Sequential
RESERVE (10) 56h Sequential
REZERO UNIT 01h Sequential
SEEK (6) 0Bh Sequential
SEEK (10) 2Bh Sequential
SEND DIAGNOSTIC 1Dh Sequential
SET DEVICE IDENTIFIER A4h Sequential
START STOP UNIT 1Bh Sequential
SYNCHRONIZE CACHE 35h Sequential
TEST UNIT READY 00h Immediate
VERIFY 2Fh Normal
WRITE (6) 0Ah Normal
WRITE (10) 2Ah Normal
WRITE AND VERIFY 2Eh Normal
WRITE BUFFER 3Bh Sequential
WRITE LONG 3Fh Sequential
WRITE SAME 41h Sequential
WRITE SKIP MASK EAh Normal